To update parameters used in reports, use the command unit/update_report_settings:
svc=unit/update_report_settings¶ms={"itemId":<long>, "params":{ "speedLimit":<uint>, "maxMessagesInterval":<uint>, "dailyEngineHoursRate":<uint>, "urbanMaxSpeed":<uint>, "mileageCoefficient":<double>, "speedingTolerance":<uint>, "speedingMinDuration":<uint>, "speedingMode":<uint> "fuelRateCoefficient":<uint> }}
| Name | Description |
|---|---|
| itemId | unit ID |
| params | parameters |
| speedLimit | speed limit, km/h |
| maxMessagesInterval | maximum interval between messages, seconds |
| dailyEngineHoursRate | daily engine hours rate, hours |
| urbanMaxSpeed | urban speed limit, km/h |
| mileageCoefficient | mileage coefficient |
| speedingTolerance | allowed speeding, km/h (used if speedingMode = 1) |
| speedingMinDuration | min speeding time, seconds |
| speedingMode | speeding detection mode: 0 - use speedLimit, 1 - use map data |
| fuelRateCoefficient | Consumption by rates, l/100km |
If speedingMode = 0 and speedLimit = 0 then no any speeding table is built.
{} /* empty object if execution successful, if not - error code */